The inspection process allows for the Building Division to verify that the work being done by the contractor or homeowner is meeting the minimum requirements as described in the 2014 North Dakota State Building Code.

 

The following inspections are the most common required inspections. Additional inspections may be required depending on the project. All construction must meet the requirements outlined in the 2014 North Dakota State Building Code.

 

THE ADDRESS OF THE SITE MUST BE POSTED AT ALL TIMES AND THE PERMIT AND PLANS MUST ALWAYS BE ACCESSIBLE ON THE BUILDING SITE

 

  1. Footing: Call when footing forms and reinforcing are in place, but prior to the placement of any concrete.

  2. Foundation Wall: Call when wall forms are complete and all reinforcing is in place, but prior to the placement of any concrete.

  3. Drain Tile Inspection: Call when damp proofing and drain tile is in place and being covered with gravel, but prior to backfilling. 

  4. Concrete Slab: Call when forms are complete and all reinforcing is in place, but prior to the placement of any concrete.

  5. Framing: Call when structural components are complete but prior to concealing with insulation or finishes. NOTE: All electrical and plumbing rough in must be in place.

  6. Insulation: Call when all insulation is complete, when all windows, doors, and exterior weather barriers are in place.

  7. Final: Call when project is complete and the State Electrical Inspector and the State Plumbing Inspector has signed off on the project. A final inspection must be done prior to occupying the structure.